EPR Insulated Building Wire
EPR insulated building wires are irreplaceable in harsh environments such as high temperatures, corrosion, and frequent bending, especially for industrial and infrastructure applications that require high reliability and long life. Conform to UL44, IEC60245, DIN VDE 0207 and EN50525.
Category:
Building Wire
Keywords:

1、Description
EPR insulated building wires are irreplaceable in harsh environments such as high temperatures, corrosion, and frequent bending, especially for industrial and infrastructure applications that require high reliability and long life. Conform to UL44, IEC60245, DIN VDE 0207 and EN50525.
2、Construction
Conductor
IEC60228 class 5 or 6, copper conductor
Insulation
EPR
Sheath(optional)
Rubber sheath
3、Application
Fixed wiring, civil power, mobile equipment. Working temperature at 90 degree.
4、Construction Drawing
| Technical characteristics of Rubber insulated cables- IEC60245.4 YCW CABLE | ||||||
| Number and nominal area | Thickness of insulation | Thickness of sheath mm | Mean overall diameter | Approx.. mass per unit length | Maximum D.C. Resistance at 20℃ | |
| Lower limit mm | Upper limit mm | |||||
| No./mm2 | mm | mm | mm | mm | kg/km | Ω/km |
| 2x35 | 1.4 | 3.9 | 27.3 | 34.6 | 1383 | 0.554 |
| 2x50 | 1.6 | 4.3 | 31.8 | 40.1 | 1880 | 0.386 |
| 2x70 | 1.6 | 4.6 | 35.8 | 45.1 | 2525 | 0.272 |
| 2x95 | 1.8 | 5.0 | 40.2 | 51.0 | 3292 | 0.206 |
| 3×120 | 1.8 | 5.6 | 47.3 | 60.0 | 5355 | 0.161 |
| 3×150 | 2.0 | 6.0 | 52.0 | 66.0 | 6626 | 0.129 |
| 3×2.5+1×1.5 | 0.9/0.8 | 1.8 | 11.5 | 14.7 | 248 | 7.98/13.3 |
| 3×4+1×2.5 | 1.0/0.9 | 2.0 | 13.6 | 17.3 | 351 | 4.95/7.98 |
| 3×6+1×4 | 1.0/1.0 | 2.2 | 15.2 | 19.4 | 475 | 3.30/4.95 |
| 3×10+1×6 | 1.2/1.0 | 3.3 | 19.9 | 25.3 | 878 | 1.91/3.30 |
| 3×16+1×6 | 1.2/1.0 | 3.5 | 22.2 | 28.1 | 1150 | 1.21/3.30 |
| 3×25+1×10 | 1.4/1.2 | 3.9 | 26.9 | 34.0 | 1689 | 0.780/1.91 |
| 3×35+1×10 | 1.4/1.2 | 4.1 | 29.5 | 37.3 | 2,083 | 0.554/1.91 |
| 3×50+1×16 | 1.6/1.2 | 4.5 | 34.2 | 43.2 | 2755 | 0.386/1.21 |
| 3×70+1×25 | 1.6/1.4 | 4.9 | 39.2 | 49.4 | 3773 | 0.272/0.780 |
| 3×95+1×35 | 1.8/1.4 | 5.3 | 44.0 | 55.4 | 4894 | 0.206/0.554 |
| 3×120+1×35 | 1.8/1.4 | 5.6 | 47.6 | 60.0 | 5794 | 0.161/0.554 |
| 3×150+1×50 | 2.0/1.6 | 6.1 | 53.0 | 67.0 | 7293 | 0.129/0.386 |
| 3×2.5+2×1.5 | 0.9/0.8 | 1.9 | 12.4 | 15.9 | 295 | 7.98/13.3 |
| 3×4+2×2.5 | 1.0/0.9 | 2.2 | 14.8 | 18.9 | 424 | 4.95/7.98 |
| 3×6+2×4 | 1.0/1.0 | 2.4 | 16.7 | 21.3 | 574 | 3.30/4.95 |
| 3×10+2×6 | 1.2/1.0 | 3.4 | 21.2 | 26.9 | 969 | 1.91/3.30 |
| 3×16+2×6 | 1.2/1.0 | 3.6 | 23.3 | 29.5 | 1204 | 1.21/3.30 |
| 3×25+2×10 | 1.4/1.2 | 4.0 | 28.2 | 35.6 | 1817 | 0.780/1.91 |
| 3×35+2×10 | 1.4/1.2 | 4.2 | 30.6 | 38.7 | 2188 | 0.554/1.91 |
| 3×50+2×16 | 1.6/1.2 | 4.6 | 35.5 | 44.7 | 3002 | 0.386/1.21 |
| 3×70+2×25 | 1.6/1.4 | 5.0 | 40.9 | 52.0 | 4148 | 0.272/0.780 |
| 3×95+2×35 | 1.8/1.4 | 5.5 | 46.2 | 58.0 | 5412 | 0.206/0.554 |
| 3×120+2×35 | 1.8/1.4 | 5.8 | 49.4 | 62.0 | 6328 | 0.161/0.554 |
| 3×150+2×50 | 2.0/1.6 | 6.3 | 55.0 | 70.0 | 7992 | 0.129/0.386 |
| YCW450/750V Cable: DC Resistance of Conductor at 20℃, Maximum Single Wire Diameter, and Minimum Insulation Resistance at 20℃ Table 4 | |||
| Section m㎡ | DC resistance of conductor at 20℃, Ω/km | Maximum single filament diameter (mm) | Minimum insulation resistance at 20℃ (MΩ*km) |
| 1.5 | 13.3 | 0.26 | 11 |
| 2.5 | 7.98 | 0.26 | 10 |
| 4 | 4.95 | 0.31 | 8 |
| 6 | 3.3 | 0.31 | 7 |
| 10 | 1.91 | 0.41 | 7 |
| 16 | 1.21 | 0.41 | 7 |
| 25 | 0.78 | 0.41 | 6 |
| 35 | 0.554 | 0.41 | 6 |
| 50 | 0.386 | 0.41 | 6 |
| 70 | 0.272 | 0.51 | 6 |
| 95 | 0.206 | 0.51 | 6 |
| 120 | 0.161 | 0.51 | 6 |
| 150 | 0.129 | 0.51 | 5 |
| YCW 450/750V Cable Structure Parameters - Continued from Table 1 | |||||
Specifications mm² | conductor diameter mm | Nominal insulation thickness mm | sheath mm | Specifications mm | Specifications mm |
| 4*2.5+1*1.5 | 2.0/1.5 | 0.9/0.8 | 2 | 12.9~16.5 | 311 |
| 4*4+1*2.55 | 2.5/2.0 | 1.0/0.9 | 2.2 | 15.2~19.4 | 448 |
| 4*6+1*4 | 3.2/2.5 | 1.0/1.0 | 2.4 | 17.0~21.6 | 602 |
| 4*10+1*6 | 4.3/3.2 | 1.2/1.0 | 3.5 | 22.1~28.0 | 1052 |
| 4*16+1*6 | 5.3/3.2 | 1.2/1.0 | 3.7 | 24.7~31.3 | 1359 |
| 4*25+1*10 | 7.0/4.3 | 1.4/1.2 | 4.2 | 30.1~38.0 | 2056 |
| 4*35+1*10 | 8.0/1.2 | 1.4/1.2 | 4.4 | 33.2~41.9 | 2564 |
| 4*50+1*16 | 9.6/5.3 | 1.6/1.2 | 4.9 | 38.7~48.7 | 3523 |
| 4*70+1*25 | 11.5/7.0 | 1.6/1.4 | 5.3 | 44.1~56.0 | 4767 |
| 4*95+1*35 | 13.3/8.0 | 1.8/1.4 | 5.8 | 49.7~63.8 | 6288 |
| 4*120+1*35 | 15.0/8.0 | 1.8/1.4 | 6.2 | 54.0~68.0 | 7421 |
| 4*150+1*50 | 16.8/9.6 | 2.0/1.6 | 6.7 | 60.0~75.0 | 9362 |
| 5*35 | 8.0 | 1.4 | 4.4 | 32.0~40.4 | 2970 |
Note: Customer’s specification are available upon request
Get in Touch Today
Need help? We’re here for you anytime!
Tel / WhatsApp:
Address
No.277, Boxue Road, Zhengdong New District, Zhengzhou City, Henan Province, china.
Previous
Factory Overview
Guided by the “Four Hearts” philosophy—dedication to products, comfort for livestock and poultry, satisfaction in feeding, and joy in investment—Nine Herdsman continuously optimizes product performance and user experience, empowering customers to adopt a new model of automated, modernized, and intensive animal husbandry.
Our service guarantee
The company's main products include Power Cables, Overhead Conductors and Insulated Conductors, Control Cables, Instrument cables, Concentric Cables, Construction Wires And Special Cables. Meanwhile, we also provide customized wire and cable solutions for customers. All series of products have obtained a number of national and international certifications.
Pre-Sales Advantages
Senide Power's pre-sales team not only excels in multiple languages but also possesses deep expertise in the differences between international standards such as IEC, BS, and ASTM, and domestic GB standards.
Company Advantages
Our comprehensive range of products—including power cables, control cables, special cables, and building wires—has obtained multiple national and international authoritative certifications.
Company Advantages
Cynid Electric Power is not merely a processing plant, but a comprehensive manufacturing enterprise integrating R&D, design, manufacturing, sales, installation, and maintenance.
24/7 After-Sales Service
We not only provide standard warranty coverage but also guarantee a response to technical requests within 48 hours. When necessary, we will dispatch senior engineers to your site to collaborate on resolving issues.
Need help? We’re here for you anytime!
Please fill in your information, and our team will contact you as soon as possible.
More products
The products have already been used in grid system, power grid, industrial and Marine cable, new energy, Railway and other fields.
Email:admin@cynidelectric.com
Tel / WhatsApp:+8617596508896
Address: No.277, Boxue Road, Zhengdong New District,
Zhengzhou City, Henan Province, china.
Leave a Message
Powering Global Connection Connecting The World'S Power Grid